Optimization of the optical system for electron cyclotron emission imaging diagnostics on the HL-2A tokamak

  • The optical system of the electron cyclotron emission imaging diagnostics on the HL-2A tokamak has been optimized in both the narrow zoom pattern and the wide zoom pattern. The two main features of the improved optical system are (1) larger coverage of the measurement region in the plasma and (2) a flatter imaging surface. The new optics has good focal characteristics over the whole plasma cross section. The curvature of the field of the image surface (ΔR between the core channel and the edge channel) is within 5.3 cm in the narrow zoom pattern and 6.7 cm in the wide zoom pattern after optimization, whereas the values with the present optics were 23 cm in the narrow zoom pattern and 15 cm in the wide zoom pattern. The optics will be fabricated, tested and
    installed on the HL-2A tokamak before the next experimental campaign.