Lei LI (李磊), Le HAN (韩乐), Pengfei ZI (訾鹏飞), Lei CAO (曹磊), Tiejun XU (许铁军), Nanyu MOU (牟南瑜), Zhaoliang WANG (王兆亮), Lei YIN (殷磊), Damao YAO (姚达毛). Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target[J]. Plasma Science and Technology, 2021, 23(9): 95601-095601. DOI: 10.1088/2058-6272/ac0689
Citation: Lei LI (李磊), Le HAN (韩乐), Pengfei ZI (訾鹏飞), Lei CAO (曹磊), Tiejun XU (许铁军), Nanyu MOU (牟南瑜), Zhaoliang WANG (王兆亮), Lei YIN (殷磊), Damao YAO (姚达毛). Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target[J]. Plasma Science and Technology, 2021, 23(9): 95601-095601. DOI: 10.1088/2058-6272/ac0689

Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target

  • The divertor target components for the Chinese fusion engineering test reactor (CFETR) and the future experimental advanced superconducting tokamak (EAST) need to remove a heat flux of up to ∼20 MW m−2 . In view of such a high heat flux removal requirement, this study proposes a conceptual design for a flat-tile divertor target based on explosive welding and brazing technology. Rectangular water-cooled channels with a special thermal transfer structure (TTS) are designed in the heat sink to improve the flat-tile divertor target’s heat transfer performance (HTP). The parametric design and optimization methods are applied to study the influence of the TTS variation parameters, including height (H), width (W* ), thickness (T), and spacing (L), on the HTP. The research results show that the flat-tile divertor target’s HTP is sensitive to the TTS parameter changes, and the sensitivity is T > L > W* > H. The HTP first increases and then decreases with the increase of T, L, and W* and gradually increases with the increase of H. The optimal design parameters are as follows: H = 5.5 mm, W* = 25.8 mm, T = 2.2 mm, and L = 9.7 mm. The HTP of the optimized flat-tile divertor target at different flow speeds and tungsten tile thicknesses is studied using the numerical simulation method. A flat-tile divertor mock-up is developed according to the optimized parameters. In addition, high heat flux (HHF) tests are performed on an electron beam facility to further investigate the mock-up HTP. The numerical simulation calculation results show that the optimized flat-tile divertor target has great potential for handling the steady-state heat load of 20 MW m−2 under the tungsten tile thickness <5 mm and the flow speed …7ms−1 . The heat transfer efficiency of the flat-tile divertor target with rectangular cooling channels improves by ∼13% and ∼30% compared to that of the flat-tile divertor target with circular cooling channels and the ITER-like monoblock, respectively. The HHF tests indicate that the flat-tile divertor mock-up can successfully withstand 1000 cycles of 20 MW m−2 of heat load without visible deformation, damage, and HTP degradation. The surface temperature of the flat-tile divertor mock-up at the 1000th cycle is only ∼930 °C. The flat-tile divertor target’s HTP is greatly improved by the parametric design and optimization method, and is better than the ITER-like monoblock and the flat-tile mock-up for the WEST divertor. This conceptual design is currently being applied to the engineering design of the CFETR and EAST flat-tile divertors
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return