High Magnetic Field Shielding for Sensitive Devices Relevant to ITER
-
Graphical Abstract
-
Abstract
High magnetic field shielding has been increasingly important for engineering design in recent years. In this report, a cylindric shield made from soft iron is studied using FEM (finite element method) analysis and compared with experiments. The residual fields inside the shield are calculated and measured in both parallel and perpendicular fields up to 2000 Gs. The calculated results are compared with the experiments, and the input B-H curve is modified for a better conformity. The results indicate that the covers could greatly improve the shielding performance of the cylindric shield in our research. The comparison result shows that a proper B-H curve, which can well describe the material properties, is very important in FEM analysis and should be selected carefully.
-
-