Advanced Search+
Chen ZHOU (周晨), Yueying LI (李玥颖), Zhi YU (俞鸷), Jingfeng YAO (姚静锋), Chengxun YUAN (袁承勋), Zhongxiang ZHOU (周忠祥). Diagnostics of a microhollow cathode discharge at atmospheric pressure[J]. Plasma Science and Technology, 2021, 23(6): 64001-064001. DOI: 10.1088/2058-6272/abe3e2
Citation: Chen ZHOU (周晨), Yueying LI (李玥颖), Zhi YU (俞鸷), Jingfeng YAO (姚静锋), Chengxun YUAN (袁承勋), Zhongxiang ZHOU (周忠祥). Diagnostics of a microhollow cathode discharge at atmospheric pressure[J]. Plasma Science and Technology, 2021, 23(6): 64001-064001. DOI: 10.1088/2058-6272/abe3e2

Diagnostics of a microhollow cathode discharge at atmospheric pressure

  • Based on a sandwich-like structure, a microhollow cathode discharge device is designed, and a stable discharge is realized by injecting helium into the discharge region of the device at atmospheric pressure. A wall probe is used to determine the relevant parameters of the plasma generated by the device, such as particle density, electron temperature, and the electron distribution function. At the same time, a sink parameter is used to correct the electron distribution function of the wall-probe diagnostics, and to further study the relationship between electron density and the electron temperature of the corrected electron distribution function.