Processing math: 100%
Advanced Search+
Xu ZHOU, Xianhui CHEN, Taohong YE, Minming ZHU, Weidong XIA. Numerical study of the effect of coflow argon jet on a laminar argon thermal plasma jet[J]. Plasma Science and Technology, 2022, 24(5): 055409. DOI: 10.1088/2058-6272/ac52eb
Citation: Xu ZHOU, Xianhui CHEN, Taohong YE, Minming ZHU, Weidong XIA. Numerical study of the effect of coflow argon jet on a laminar argon thermal plasma jet[J]. Plasma Science and Technology, 2022, 24(5): 055409. DOI: 10.1088/2058-6272/ac52eb

Numerical study of the effect of coflow argon jet on a laminar argon thermal plasma jet

More Information
  • Corresponding author:

    Xianhui CHEN, E-mail: chenxian@mail.ustc.edu.cn

    Taohong YE, E-mail: thye@ustc.edu.cn

  • Received Date: December 13, 2021
  • Revised Date: January 29, 2022
  • Accepted Date: February 07, 2022
  • Available Online: December 11, 2023
  • Published Date: May 19, 2022
  • The effects of the velocity and width in coflow argon jet inlet on the flow characteristics of laminar argon thermal plasma jet flowing into the cold air have been studied by the large eddy simulation methods. The Kelvin–Helmholtz instability between argon thermal plasma jet and coflow argon jet causes the transition from a laminar jet to a turbulent jet in the presence of coflow argon jet. Moreover, increasing the velocity and width in coflow argon jet inlet can enhance turbulent transport and provoke coherent structure in the downstream of thermal plasma jet. And the mixing characteristics between argon thermal plasma, coflow argon and ambient air are strengthened. In addition, the width in coflow argon jet inlet has a significant effect on the distribution of temperature in the upstream of thermal plasma jet. It was also found that the transition occurs in advance with the increase of velocity and width in coflow argon jet inlet.

  • It is well known that during edge localized mode instabilities in magnetic fusion devices, the disruption of the plasma filament and the production of the heat and particle fluxes occur on the wall of the reactors. As a result, the plasma-facing material surface is damaged and dust particles are created. All of these events negatively affect the safety and normal operation of the reactor. As an example, dust ejection into the plasma core volume leads to the contamination of the discharge and may contribute to tritium safety issues [1].

    In studies [25], the disruption and plasma-wall interaction simulation experiments were performed at the plasma accelerators. As a potential candidate material for the first wall, the graphite was chosen in [2, 3]. The graphite plate was irradiated with the high-energy plasma flux generated in a coaxial plasma accelerator. In work [4] a quasi-stationary pulsed plasma accelerator was used to provide high heat plasma flux, which is expected during operation of an international thermonuclear experimental reactor, and to study the damage of divertor plasma-facing components with a combination of the pulsed and quasi-stationary heat fluxes. In that work the tungsten target was used as a candidate material of the divertor. In work [5] a pulsed coaxial plasma gun was assembled to investigate the dependence plasma flow structure on initial operating working gas pressure at 'continuously filled' regime. In studies [68] new design and construction of pulsed plasma accelerators intended for creation of dense pinch plasma focus discharges were presented. Moreover, in this work, the impact of the electrode system on the neutron yield, x-ray radiation in a dense pinch plasma focus was investigated.

    As mentioned above, one of the applications of plasma accelerators is the experimental simulation of the plasma filament compression and disruption in magnetic fusion devices and Z-pinches [9, 10]. For these purposes, recently we have modified the coaxial plasma accelerator by installing more capacitive and low-inductive energy storage capacitors and also by using electrical coupling cables with low reactive impedance. In addition, the avoidance of reverse reflected plasma flow from the end of the accelerator is taken into account. It was achieved by using a special plasma-absorbing target installed inside the vacuum chamber. This constructive modification allows obtaining plasma flow with its self-magnetic field and the relatively long body filament. Those changes give the opportunity to experimentally simulate the processes occurring in the plasma filament. The main purpose of this work is to conduct complex plasma diagnostics for studying the physical properties and plasma flow formation dynamics in the channel of modified plasma accelerator. There is a wide spectrum of diagnostic methods for the investigation of the plasma filament and its basic parameters in CPA at extreme conditions (at high temperatures and plasma densities, at high frequency oscillations created in an accelerator by pinch discharges). Of these, some of the frequently used electrical signal measurement-based techniques for plasma diagnostics such as Rogowski coil, Faraday cup, and magnetic probes, were utilized. Furthermore, high-speed imaging techniques, for visual observation of the accelerated plasma, were used.

    The work novelty is summarized as follows: in comparison with related former researches, this work considers the most important physical properties of plasma flow and the physical processes, such as charge separation (electrons and ions) in plasma flow with FC, compression and disruption of plasma filaments using frames synchronized with magnetic probe signals.

    A principle scheme of the coaxial plasma accelerator is shown in figure 1. An experimental setup consists of two concentric (coaxial) copper electrodes: an inner anode and an outer cathode. Anode and cathode are isolated by a dielectric material. The operational principle of experimental setup is based on the acceleration of plasma generated by ionization of gas filling in interelectrode space, when a high-voltage is supplied to the electrodes. The acceleration takes place due to the J × B force acting on plasma. A vacuum arrester was used for the transfer of capacitor-stored energy to the gas between two electrodes. The installation design and its operational principle are described in detail elsewhere [1114].

    Figure  1.  A principle scheme of the coaxial plasma accelerator.

    The power system of the CPA includes a low-inductive capacitor banks with five parallel- connected capacitors of the KPIMK-8-288 type (288 μF). The total capacitance is 1.44 mF and maximum energy stored on the capacitors at a maximum charging operating voltage of 6 kV is W = 26 kJ.

    The current flowing through the electric circuit of the CPA was measured by a Rogowski coil [15] with the ~75 mm diameter loop and L = 27.5 μH inductance.

    The magnitudes of magnetic fields generated by pulsed plasma flow in space between two concentric electrodes and at the out of an accelerator were measured using two magnetic probes (No. 1 and No. 2 in figure 1). The dimension and characteristics of each probe are as follows: number of turns n = 7, loop radius r = 1.1 mm, loop cross-sectional area A = 3.8 mm2, time constant τ = L/R = 2.3 ns [16]. The winding ends of magnetic probes were twisted and brought out. Then they were connected to the BNC cable attached to the end of glass tube. The impedance of this cable is 50 Ω. The BNC cable was used to connect the twisted pair terminals of magnetic probes to the oscilloscope through a passive RC integrator circuit (RC = 100 μs).

    The formation, dynamics and development of pulsed plasma flow inside the CPA vacuum chamber were captured by the high-speed Phantom VEO710S CMOS camera [17]. The plasma flow velocity was measured by analyzing the obtained images. The frequency and exposure time of the high-speed camera were 280 000 frames s-1 and 3.1 μs respectively.

    The Faraday cup with 160 μm orifice [18] was used to measure the electron and ion currents, energy and densities of charged particles of plasma flow.

    All signals were recorded on the digital storage oscilloscope LeCroy WaveJet 354 A, 500 MHz/4-channel. Also, Berkeley Nucleonics pulse generator (model 577) with an external synchronizing plasma-created signal was used to trigger the scope and CMOS camera in the external trigger mode.

    All the experiments were carried out at voltages varied between 2 and 6 kV and at a plasma-forming gas pressures varied between 0.03 and 11 Torr. Two types of gases such as hydrogen, residual air were used as a plasma source. An electrical discharge was initiated by a high-voltage vacuum gap with a residual pressure of ~10-2 Torr.

    This section presents the results of plasma diagnostics using the methods described above: (i) Rogowski coil, (ii) magnetic probe and Faraday cup, (iii) high-speed CMOS camera.

    For controlling the operation of plasma accelerators, it is important to know the value of the current flowing through its driving circuit. In this regard, the typical current oscillograms and IV characteristic of the CPA, obtained for the two types of working gas, shown in figures 2(a) and (b). These discharge current oscillograms are in well agreement with the oscillograms presented in other studies [19, 20] and represent a rapidly damping waveform. This indicates a low inductance of the system and demonstrates the fact of effective transfer of the energy stored in the capacitors. The use of air as the working gas for plasma generation is most convenient for conducting preliminary experiments.

    Figure  2.  (a) The typical current waveforms and (b) the current dependence on the voltages supplied to the capacitor banks (IV characteristics of the CPA).

    In this work, with a 5 kV charging voltage and 60 mTorr gas pressure, we could reach the maximum current values of 80 kA for the air and 65 kA for the hydrogen, respectively. From obtained IV characteristics of the CPA (figure 2(b)) one can see that the maximum current linearly increases with increasing the charging voltage supplied to the capacitor banks. We explain this by the insignificant contribution of the pulsed plasma active resistance and the absence of current skipping. In this case, it can be considered that the maximum current Imax flowing through the CPA driving circuit is proportional to the applied voltage U. A relevant IV characteristic can be also found in [21].

    Also, the dependence of the discharge current on the hydrogen gas pressure was obtained in this work (figure 3(a)). This graph shows that the current initially increases to its absolute value, and then it gradually decreases with increasing the pressure of hydrogen in the vacuum chamber. We explain this result by increasing the inductance and inductive resistance of the CPA circuit, which occurs while forming long-lived plasma filaments. The absolute value of the discharge current was measured at pressure of 1.2 Torr. A relevant dependence was also presented in studies [22, 23]. The dependence of the plasma filament's self-magnetic field on the hydrogen pressure was shown in figure 3(b). As can be seen in figure 3(b), the magnitude of the magnetic field decreased more than twofold with tenfold increasing gas pressure. At higher gas pressures of 2–4 Torr, the magnetic field magnitude almost did not change.

    Figure  3.  The dependence of the discharge current (a) and the self-generated magnetic field of plasma flow (b) on the gas pressure.

    Thus, the experimentally confirmed optimal gas pressure in the CPA is about 200 mTorr, because at this pressure it allowed us to achieve the maximum value of the plasma filament's self-magnetic field. In this regard, the experiments were performed at pressures at which the maximum plasma compression (Z-pinch) was achieved. Consequently, these provide us for steady focusing of the plasma flux to the axis of the vacuum chamber.

    It can be seen from the obtained results shown in figure 3, that the absolute values of the magnetic field and the discharge current are observed at various gas pressures in the vacuum chamber. Therefore, a small change in the discharge current leads to a significant change in the plasma filament's self-magnetic field.

    The typical images of the formation of plasma flow in hydrogen gas, obtained in one pulse shot at voltages of 4 kV and gas pressure of 2 Torr, through the quartz viewing side window of the vacuum chamber, are shown in figure 4(b). It should also be noted that the time evolution of the images matches with the time dependence of the magnetic probe signal shown in figure 4(a) (the CMOS camera was synchronized with the discharge in the experiment). The typical magnetic probe signals as in figure 4(a) were presented in [24].

    Figure  4.  (a) The typical oscillograms of the plasma filament's self-magnetic field and (b) the instaneous images of the formation of pulsed plasma flow (side view).

    Figure 4(b) shows the plasma flux formation and acceleration frames recorded by using a high-speed camera. The camera frequency, resolution and exposure time are 280 000 frames s-1, 256 × 64, 3.1 μs. These frames were registered in a single pulse, but at different time moments. In figure 4(b), plasma acceleration direction is from the left to the right. The time moment of the vacuum arc discharge ignition between the coaxial cylindrical electrodes was fixed as the initial reference point. A high-current arc discharge produces strong self-induced magnetic field. Thus, plasma is accelerated toward the cathode tip by electromagnetic forces. As can be seen in figure 4(b)I, the head of the accelerated plasma flux was registered at a time of 17.8 μs. At the same time, as can be seen from the oscillograms, the magnetic probe No. 1, placed between inner and outer electrodes registered the magnitude of the magnetic fields with an absolute value of the order of ~0.3 T, while the magnetic probe No. 2 did not register this field. The magnetic probe No. 2 was shielded by a ferromagnetic material with a 1 mm side slit. Respectively, it was sensitive only to the magnetic field created by the plasma flux current, flowing via the area where the magnetic probe No. 2 is located. Then, in the subsequent frame, at t = 21.4 μs, the visible region of the high-speed camera is completely filled with bright plasma, and plasma flow with a duration of more than ~70 μs is formed (figure 4(b)II). At this time moment, plasma flow passes the vacuum chamber cross section, where the magnetic probe No. 2 is mounted, and the voltage is gradually induced at its winding ends. Thus, the magnetic field first increases to a maximum value of ~0.6 T, and then decreases. The magnetic field fluctuations are observed in the CPA at relatively high gas pressures, but they have a tendency to decay as the pressure increases. In this case, it can be assumed that instability occurs in the CPA due to the anomalous plasma resistance, and subfilament-type structures are formed. Therefore, the voltage decreasing from its absolute value on the probe No. 2 and its fluctuation are explained with the plasma flux compression and disruption with its self-magnetic field. Thus, in one pulse, the plasma filament is disrupted into multiple sub-filaments. These indicate the creation of an inhomogeneous plasma fluxes. The estimated from two consecutive frames first sub-filament duration and directional velocity are ~70 μs, ~25.5 km s-1 (figure 4(b)I). The following sub-filament was recorded after 96.4 μs (figure 4(b)III). The frame shown in figure 4(b)IV (140–160 μs) corresponds to the third peak of the magnetic probe signal No. 2 with amplitude of 0.1 T (figure 4(a)).

    Figures 5(a) and (b) show the measured values of the magnetic field at a distance of 23.5 cm from the tip of the cathode and in space between the electrodes as a function of the charging voltage supplied to the capacitor banks. One can see that the value of the magnetic field in both cases increases proportionally with the voltage. Furthermore, the values of the magnetic field are on average 30% higher when the pure hydrogen is used as the plasma-forming gas than in case of the residual air. The physical interpretation of this phenomenon has not yet been revealed.

    Figure  5.  The dependence of the plasma filament's self-magnetic field on the voltage supplied to the capacitor banks: (a) at a distance of 23.5 cm from the cathode tip and (b) in the space between the electrodes.

    As can be seen from the oscillogram in figure 6(b), the increase in pressure up to 11 Torr leads to a decrease in amplitude of the No. 2 magnetic probes signal. Note that probe No. 2 was positioned at a 23.5 cm distance from the cathode tip, due to the fact that at this position the vacuum chamber-viewing window is located. Therefore, this distance is the most convenient and closest for observation by the high-speed camera. Moreover, the signal from the magnetic probe in interelectrode space repeats the current fluctuation in the accelerator circuit in comparison with figure 5(a) obtained at p = 60 mTorr. This indicates that, when the gas pressure is high, the resistance of the medium becomes larger, and as a result, the flow rate decreases, the primary plasma sub-filament is concentrated in interelectrode space. We also assume that this is due to an increase in mass of the plasma bullet, which can also affect the acceleration of plasma flow. One can see from figure 6(b), at higher pressures in the vacuum chamber, both positive and negative peaks appear in the oscillogram of the magnetic field.

    Figure  6.  The oscillograms of magnetic probes obtained at gas pressures: (a) p = 60 mTorr, (b) p = 11 Torr.

    This fact shows the separation of plasma charges. The charge separation in plasma flow during the accelerating along the axis of the vacuum chamber can be observed in the FC signal also. When the FC collector voltage is zero, two peaks of opposite polarity are observed on the oscillogram (see figure 7). This happens when the collector of a FC is bombarded first by the electron and then by the ion beams, due to the center of a mass shift in space. We assume that this is firstly related to the principle of plasma flow acceleration in this type of accelerators and, secondly, to the collision processes between the particles: generally between directed ions and thermal neutrals. When the pressure of the gas in the vacuum chamber increases, the number of neutral particles increases too, resulting in an increased frequency of collisions of plasma charges with neutral particles. So, when neutrals collide frequently with ions, the ions begin to be slowed down. During this, the electrons have enough time to separate from the ions at a certain distance along the axis of acceleration.

    Figure  7.  The ion and electron current waveforms.

    The plasma accelerators are known as potential sources of a wide variety of radiation such as electrons, ions, neutrons and x-rays, which has great interest for different applications. It is very important to investigate the ion beams and its general characteristics, such as energy, density, and uniformity for material processing, surface modification, ion implantation etc. In this regard, in this work we fabricated and employed FC for measuring the density of ions in plasma flux. In the experiment, FC was mounted in the path of the plasma flux. The resulting current of accelerated plasma particles absorbed by the collector was measured using an oscilloscope. The typical oscillogram at zero voltage on the collector, as well as at a potential of ±40 V is shown in figure 7 as an example.

    At zero voltage on the oscillogram one can observe peaks of negative and positive polarity, which is associated with the flux of electrons and ions with a time difference (70–75 μs), and indicates the separation of charge fluxes in plasma. After furthermore analysis of this result, we concluded, that for such a long period of time charge separation is not probable. Because time difference estimation is approximate and is obtained only on the waveform at zero voltage. It should be noted, that charge separation occurs, but only in a short time interval. Therefore, the ion beam current can be appeared earlier than the estimated time. We cannot see this from the FC oscillograms, obtained at zero collector potential, because the ion current can be very low and it can also be dampened by the electron current. The charge fluxes separation in plasma flow occurs in 5 μs, which is evaluated by applying a certain value of negative and positive potential to the collector. As the collector potential increases, for example, positive potential (+40 V), electrons will be attracted and ions will be rejected. In that case, the amplitude of the negative polarity current will increase on the oscillogram. When the potential is negative (–40 V), the amplitude of the current of positive polarity, i.e. ions, increases. The electron and ion currents do not flow to the collector simultaneously at the same collector voltages, as seen in figure 7. The time difference between two current signals is 5 μs. This can be explained by the fact that the collector adsorbs electrons and ions which are separated in space.

    Thus, the dependence of electron beam current on the collector voltage was obtained. The obtained IV characteristic will be the same as that of the single planar probe, therefore for calculations of the electron temperature, we will use the expression (1), derived from the theory and assumption of the single probe that the particle energy distribution must be Maxwellian

    Te=kedlnIedV, (1)

    where e—lectrical charge, k—Boltzmann's constant, Ie —the current of electrons, V —probe potential.

    The thermal velocity of ions is required to know to calculate their density. This can be estimated using Bohm criterion as follows:

    υi=kTeMi, (2)

    where Mi —ion mass, Te —electron temperature. Then, the density of ions is calculated by the following expression:

    ni=IiSqυi, (3)

    where Ii —ion saturation current, S —area of the orifice, q —electrical charge.

    In our case, we assume that the plasma particle velocity distribution is Maxwellian, since the directional velocity of plasma flow calculated by the high-speed camera is 2.5 × 104 m s-1, which is much less than the thermal velocity of electrons. The temperature of the electrons in this work was estimated from the slope of the Faraday cup IV characteristic plotted on a logarithmic scale and obtained by averaging the currents measured in five repeated pulses at the same collector voltage. The averaging was performed, due to the operation of the experimental setup in the pulse mode. Thus, the calculated electron temperatures for the two types of the plasma-forming gases: air and hydrogen were 40 eV. However, as can be seen in figures 8(a) and (b), in our case, the IV characteristic of the CPA deviates strongly from the exponential one. This can be explained by the fact that experimentally it is very difficult to obtain a real IV characteristic, since plasma flows, generated in the plasma accelerator, are inhomogeneous. In addition, it is necessary to take into account the pulsed mode of operation of the accelerator, which limits the measurements in a large range and quantity. Usually, measurement errors with electric probes do not exceed 25% [25]. In our case, the estimate of the error contribution to this is no more than 10%, which is due to the operation in the pulsed mode and the small number of repetitive measurements. Consequently, considering this contribution, we can judge that the total measurement error is 35%.

    Figure  8.  I–V characteristics of electron currents on a logarithmic scale for two different gases: (a) hydrogen and (b) air.

    The calculations of the electron temperature and ion density for two types of plasma-forming gases are shown in table 1. These results were compared with other works [15, 26] and are in good agreement.

    Table  1.  The calculation results.
    Hydrogen Air
    Te (eV) ni (m-3) Te (eV) ni (m-3)
    40 3.2 × 1021 40 16 × 1021
     | Show Table
    DownLoad: CSV

    From the results of calculations, the following conclusion can be done. The temperature of electrons in plasma flow for hydrogen and residual air is practically the same. The density of ions in plasma flow, generated in residual gas is higher than that in hydrogen, which is possibly associated with multiple ionization at a higher gas breakdown voltage.

    Plasma flows, generated in high-current pulsed systems, are themselves complex objects of investigation due to the non-homogeneity of the fields and currents created by accelerating plasma. Therefore, the complex plasma diagnostics allowed us to establish representation of the formation of plasma flows in the CPA channel. In particular, it allowed us to observe such phenomena as the plasma filament disruption, the charge (electrons and ions) separation in plasma flow, even with a limited number of measurement points. These phenomena were investigated depending on the external conditions of experiments also. As a result, the optimal parameters of the experimental setup were determined: working gas pressure of 200 mTorr, capacitor bank charge voltage of 5 kV.

    As a result of the complex diagnostics, the parameters of the external electrical circuit of the CPA and the energetic, dynamic characteristics of the plasma filament were obtained. From the results obtained, it was revealed that the current curves represent rapidly damped aperiodic oscillations with a small number of half-periods. Such a condition is advantageous and indicates the low value of inductive resistance of the circuit, including connecting wires, capacitors and vacuum arrester. One can conclude from this that the stored energy is effectively transported into the discharge. Also, it was found that the current depends linearly on the voltage supplied to the capacitor banks, which is explained by the high conductivity and the low resistance of the plasma filament. In the experiment, the absolute current values of 80 and 65 kA for hydrogen and air plasma-forming gases were obtained at a maximum voltage of 5 kV and working gas pressure of 60 mTorr. With increasing gas pressure, it was found that the current amplitudes decrease from the maximum value, which is explained by an increase in inductance associated with the formation of long-lived plasma filaments. Based on the results obtained by the high-speed CMOS camera, the plasma filament disruption was also observed in the experiments, which explains a quasiperiodic ejection of plasma from space between the cathode and anode. The peaks observed in the oscillograms of the magnetic probe also indicate this phenomenon. The electron temperature and ion density in plasma flow were measured by using FC. It is shown that in the dynamic plasma, even when the collector potential is zero, currents are generated at the collector, which is explained by bombarding of the collector surface by charged particles. Therefore, in the calculations, the parasitic currents are extracted from the major currents measured at various collector bias voltages. As a result, we eliminated the influence of background currents on the error of the measurement. At the conclusion of this work, we achieved the following purposes: a physical representation of plasma flow formation in the CPA channel as a function of working gas pressure and the capacitor bank charging voltage has been established; the optimal experimental conditions were determined at which the maximum plasma filament compression can be obtained; charge fluxes separation in space relative to the common center of mass with a time difference of ~5 μs was observed by using FC; the oscillograms of magnetic probes signals and plasma flow acceleration frames simultaneously confirm plasma filament disruption. Especially it is noticeable at high pressures, which is related with an increase in the medium resistance and collision frequency of ions with neutrals. In the future, we will use these results, the new insights we have gained, and proven diagnostic methods in our fusion research work. In particular, to further modify and investigate the processes of plasma flow interaction with materials that are candidates for the fusion reactor's first-wall, and to improve the experimental setup for producing homogeneous plasma flows with the best energetic parameters.

    This work is supported by National Natural Science Foundation of China (Nos. 12035015 and 12105282). The numerical simulations in this work have been performed on the supercomputers in the Supercomputing Center, University of Science and Technology of China.

  • [1]
    Cheng K, Chen X and Pan W X 2006 Plasma Chem. Plasma Process. 26 211 doi: 10.1007/s11090-006-9006-6
    [2]
    Williamson R L et al 2003 Int. J. Heat Mass Transfer 46 4201 doi: 10.1016/S0017-9310(03)00272-2
    [3]
    Cheng K and Chen X 2004 Int. J. Heat Mass Transfer 47 5139 doi: 10.1016/j.ijheatmasstransfer.2004.06.028
    [4]
    Li H P and Chen X 2002 Plasma Chem. Plasma Process. 22 27 doi: 10.1023/A:1012988430995
    [5]
    Liu B et al 2008 IEEE Trans. Plasma Sci. 36 1076 doi: 10.1109/TPS.2008.924481
    [6]
    Xu D Y, Chen X and Cheng K 2003 J. Phys. D: Appl. Phys. 36 1583 doi: 10.1088/0022-3727/36/13/324
    [7]
    Gonzalez N Y M, El Morsli M and Proulx P 2008 J. Therm. Spray Technol. 17 533 doi: 10.1007/s11666-008-9209-x
    [8]
    Wang H X, Chen X and Li H P 2011 Plasma Chem. Plasma Process. 31 373 doi: 10.1007/s11090-011-9288-1
    [9]
    Wu G Q et al 2009 Int. J. Heat Mass Transfer 52 760 doi: 10.1016/j.ijheatmasstransfer.2008.07.043
    [10]
    Zhang T, Gawne D T and Liu B 2000 Surf. Coat. Technol. 132 233 doi: 10.1016/S0257-8972(00)00847-1
    [11]
    Planche M P, Liao H and Coddet C 2007 Surf. Coat. Technol. 202 69 doi: 10.1016/j.surfcoat.2007.04.053
    [12]
    Sobolev V V and Guilemany J M 1999 J. Therm. Spray Technol. 8 523 doi: 10.1361/105996399770350205
    [13]
    Gan J A and Berndt C C 2013 J. Therm. Spray Technol. 22 1069 doi: 10.1007/s11666-013-9955-2
    [14]
    Zeng Z, Kuroda S and Era H 2009 Surf. Coat. Technol. 204 69 doi: 10.1016/j.surfcoat.2009.06.036
    [15]
    Gawne D T, Zhang T and Liu B 2002 Surf. Coat. Technol. 153 138 doi: 10.1016/S0257-8972(01)01672-3
    [16]
    Kang K D and Hong S H 1999 J. Appl. Phys. 85 6373 doi: 10.1063/1.370140
    [17]
    Kim S et al 2010 Thin Solid Films 518 6369 doi: 10.1016/j.tsf.2010.03.154
    [18]
    Vadikkeettil Y et al 2018 Plasma Chem. Plasma Process. 38 759 doi: 10.1007/s11090-018-9890-6
    [19]
    Kai C et al 2006 Thin Solid Films 506 724
    [20]
    Mukherjee B et al 2019 ACS Appl. Mater. Interfaces 11 25500 doi: 10.1021/acsami.9b04239
    [21]
    Ranjan S et al 2020 J. Eur. Ceram. Soc. 40 660 doi: 10.1016/j.jeurceramsoc.2019.10.043
    [22]
    Boselli M et al 2013 J. Phys. D: Appl. Phys. 46 224009 doi: 10.1088/0022-3727/46/22/224009
    [23]
    Guo S F et al 2010 Plasma Chem. Plasma Process. 30 121 doi: 10.1007/s11090-009-9204-0
    [24]
    Peters J et al 2008 Plasma Chem. Plasma Process. 28 331 doi: 10.1007/s11090-008-9129-z
    [25]
    Islam A et al 2021 ACS Nano 15 1775 doi: 10.1021/acsnano.0c09451
    [26]
    Xu D Y, Chen X and Pan W X 2005 Int. J. Heat Mass Transfer 48 3253 doi: 10.1016/j.ijheatmasstransfer.2005.02.039
    [27]
    Williamson R L et al 2003 Int. J. Heat Mass Transfer 46 4215 doi: 10.1016/S0017-9310(03)00271-0
    [28]
    Pan W X et al 2001 Plasma Chem. Plasma Process. 21 23 doi: 10.1023/A:1007037327834
    [29]
    Huang P C, Hebeylein J and Pfender E 1995 Plasma Chem. Plasma Process. 15 25 doi: 10.1007/BF01596680
    [30]
    Wang H X et al 2008 Plasma Chem. Plasma Process. 28 85 doi: 10.1007/s11090-007-9109-8
    [31]
    Shigeta M 2019 IEEJ Trans. Electr. Electron. Eng. 14 16 doi: 10.1002/tee.22761
    [32]
    Shigeta M 2016 J. Phys. D: Appl. Phys. 49 493001 doi: 10.1088/0022-3727/49/49/493001
    [33]
    Shigeta M 2013 J. Phys. D: Appl. Phys. 46 015401 doi: 10.1088/0022-3727/46/1/015401
    [34]
    Shigeta M 2012 Plasma Sources Sci. Technol. 21 055029 doi: 10.1088/0963-0252/21/5/055029
    [35]
    Marchand C et al 2007 J. Therm. Spray Technol. 16 705 doi: 10.1007/s11666-007-9112-x
    [36]
    Jasak H, Jemcov A and Tukovic Z 2007 openfoam: a c++ library for complex physics simulations int. workshop on coupled methods in numerical dynamics (dubrovnik, croatia) (iuc) p 1
    [37]
    Zhou X et al 2021 Plasma Sci. Technol. 23 125405 doi: 10.1088/2058-6272/ac1f81
    [38]
    Murphy A B 1995 Plasma Chem. Plasma Process. 15 279 doi: 10.1007/BF01459700
    [39]
    Smagorinsky J 1963 Mon. Weather Rev. 91 99 doi: 10.1175/1520-0493(1963)091<0099:GCEWTP>2.3.CO;2
    [40]
    Murphy A B 1996 J. Phys. D: Appl. Phys. 29 1922 doi: 10.1088/0022-3727/29/7/029
    [41]
    Dinesh K K J and Kirkpatrick M P 2009 Comput. Fluids 38 1232 doi: 10.1016/j.compfluid.2008.11.015
    [42]
    Dinesh K K J et al 2012 Int. J. Heat Fluid Flow 33 193 doi: 10.1016/j.ijheatfluidflow.2011.10.007
    [43]
    Pfender E, Fincke J and Spores R 1991 Plasma Chem. Plasma Process. 11 529 doi: 10.1007/BF01447164
  • Related Articles

    [1]Sunil KANCHI, Rohit SHUKLA, Archana SHARMA. Study of plasma parameters of coaxial plasma source using triple Langmuir probe and Faraday cup diagnostics[J]. Plasma Science and Technology, 2024, 26(4): 045402. DOI: 10.1088/2058-6272/ad0f09
    [2]Qinghu YANG, Zhipeng CHEN, Zhigang HAO, Yangming ZHAO, Xin XU, Shuhao LI, Jie YANG, Wei YAN, Zhonghe JIANG, Zhongyong CHEN, Nengchao WANG, Zhoujun YANG, Yuan PAN, Yonghua DING, the J-TEXT Team. Design and first result of combined Langmuir-magnetic probe on J-TEXT tokamak[J]. Plasma Science and Technology, 2022, 24(5): 054005. DOI: 10.1088/2058-6272/ac41bf
    [3]Kai ZHAO (赵凯), Yongxin LIU (刘永新), Quanzhi ZHANG (张权治), Demetre J ECONOMOU, Younian WANG. Magnetic probe diagnostics of nonlinear standing waves and bulk ohmic electron power absorption in capacitive discharges[J]. Plasma Science and Technology, 2021, 23(11): 115404. DOI: 10.1088/2058-6272/ac1cce
    [4]Shuichi SATO, Hiromu KAWANA, Tatsushi FUJIMINE, Mikio OHUCHI. Frequency dependence of electron temperature in hollow cathode-type discharge as measured by several different floating probe methods[J]. Plasma Science and Technology, 2018, 20(8): 85405-085405. DOI: 10.1088/2058-6272/aabfcd
    [5]Qingquan YANG (杨清泉), Fangchuan ZHONG (钟方川), Guosheng XU (徐国盛), Ning YAN (颜宁), Liang CHEN (陈良), Xiang LIU (刘祥), Yong LIU (刘永), Liang WANG (王亮), Zhendong YANG (仰振东), Yifeng WANG (王一丰), Yang YE (叶扬), Heng ZHANG (张恒), Xiaoliang LI (李小良). Combined Langmuir-magnetic probe measurements of type-I ELMy filaments in the EAST tokamak[J]. Plasma Science and Technology, 2018, 20(6): 65101-065101. DOI: 10.1088/2058-6272/aaab43
    [6]M RACK, D HÖSCHEN, D REITER, B UNTERBERG, J W COENEN, S BREZINSEK, O NEUBAUER, S BOZHENKOV, G CZYMEK, Y LIANG, M HUBENY, Ch LINSMEIER, the Wendelstein -X Team. Probe manipulators for Wendelstein 7-X and their interaction with the magnetic topology[J]. Plasma Science and Technology, 2018, 20(5): 54002-054002. DOI: 10.1088/2058-6272/aaac78
    [7]Yong WANG (王勇), Cong LI (李聪), Jielin SHI (石劼霖), Xingwei WU (吴兴伟), Hongbin DING (丁洪斌). Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach[J]. Plasma Science and Technology, 2017, 19(11): 115403. DOI: 10.1088/2058-6272/aa861d
    [8]Satoshi NODOMI, Shuichi SATO, Mikio OHUCHI. Electron Temperature Measurement by Floating Probe Method Using AC Voltage[J]. Plasma Science and Technology, 2016, 18(11): 1089-1094. DOI: 10.1088/1009-0630/18/11/06
    [9]BAI Yujing (白玉静), LI Jianquan (李建泉), XU Jun (徐军), LU Wenqi (陆文琪), WANG Younian (王友年), DING Wanyu (丁万昱 ). Improvement of the Harmonic Technique of Probe for Measurements of Electron Temperature and Ion Density[J]. Plasma Science and Technology, 2016, 18(1): 58-61. DOI: 10.1088/1009-0630/18/1/10
    [10]YUAN Zhongcai(袁忠才), SHI Jiaming (时家明), HUANG Yong (黄勇), XU Bo (许波). Faraday angle of Linearly Polarized Waves along Magnetic Field in Magnetized Collisional Plasmas[J]. Plasma Science and Technology, 2010, 12(5): 519-522.
  • Cited by

    Periodical cited type(3)

    1. Chen, Q., Liu, L., Qin, C. et al. Development of an automatic decoupling system for ICRH antenna straps in EAST. Fusion Engineering and Design, 2025. DOI:10.1016/j.fusengdes.2025.114847
    2. Zhu, G., Li, Q., Sun, X. et al. Particle simulations on propagation and resonance of lower hybrid wave launched by phased array antenna in linear devices. Plasma Science and Technology, 2022, 24(7): 075102. DOI:10.1088/2058-6272/ac5f80
    3. Liu, L.N., Wang, L., Yuan, S. et al. Impedance matching system using triple liquid stub tuners for high-power ion cyclotron resonance heating in EAST tokamak. Review of Scientific Instruments, 2022, 93(4): 043506. DOI:10.1063/5.0076421

    Other cited types(0)

Catalog

    Figures(10)  /  Tables(3)

    Article views (119) PDF downloads (77) Cited by(3)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return