Advanced Search+
Liang LIU, Deliang YU, Qian MA, Xiaofei HE, Maarten DE BOCK, Manfred von HELLERMANN, Michael WALSH, Wenjin CHEN, Xiaoxue HE, Yanling WEI, Neng ZHANG, Dong LI, Huiling WEI, the HL-2A Team. The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak[J]. Plasma Science and Technology, 2024, 26(6): 065102. DOI: 10.1088/2058-6272/ad24f5
Citation: Liang LIU, Deliang YU, Qian MA, Xiaofei HE, Maarten DE BOCK, Manfred von HELLERMANN, Michael WALSH, Wenjin CHEN, Xiaoxue HE, Yanling WEI, Neng ZHANG, Dong LI, Huiling WEI, the HL-2A Team. The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak[J]. Plasma Science and Technology, 2024, 26(6): 065102. DOI: 10.1088/2058-6272/ad24f5

The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak

  • Charge-exchange (CX) recombination spectroscopy is a powerful tool monitoring ion temperature and plasma rotation with good temporal and spatial resolutions. A compact, new design for a high-throughput, tri-band high spectral resolution spectrometer has been developed for the charge-exchange recombination spectroscopy measurement on the HL-2A tokamak. The simultaneous measurements of He II (468.57 nm), C VI (529.1 nm), and Dα (656.1 nm accompanied by beam emission spectra) with an acquisition frequency up to 400 Hz are achieved by vertically binning the spectrum from each fiber in experiments. Initial results indicate that the system can provide radial profiles of not only ion temperature and rotation velocity, but also concentration of carbon. For the case of helium, the measurements for the ion temperature and rotation velocity are straightforward but the apparent concentration associated with the observed CX intensity is obviously too high. Modeling of the active He II CX feature including plume contributions needs to be carried out to extract the true helium concentration. The spectrometer could become a prototype for the ITER charge-exchange recombination spectroscopy diagnostic and the pilot experiments, as presented here, demonstrate the possibility of impurity concentrations measurements based on the combined measurement of local beam emission and charge-exchange recombination spectroscopy spectra.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return