Advanced Search+
YAO Xueling, CHEN Jingliang, SUN Wei. Experimental Study on Triggering Characteristics of a Surface Flashover Triggered Vacuum Switch[J]. Plasma Science and Technology, 2010, 12(6): 734-737.
Citation: YAO Xueling, CHEN Jingliang, SUN Wei. Experimental Study on Triggering Characteristics of a Surface Flashover Triggered Vacuum Switch[J]. Plasma Science and Technology, 2010, 12(6): 734-737.

Experimental Study on Triggering Characteristics of a Surface Flashover Triggered Vacuum Switch

  • Triggering characteristics of triggered vacuum switch (TVS), including the discharge delay time, delay jitter, range of operational voltage and peak of pulsed current, are investigated. Both structure and experimental circuit of TVS are presented. The results indicate that TVS, as a surface flashover triggering device with high dielectric permittivity material, is with excellent triggering characteristics. When the hold-off voltage reaches 120 kV, the minimum operational voltage is 1.3 kV, and the minimum discharge delay time and jitter are 100 ns and ?10 ns, respectively. The peak current is up to 240 kA when the operational voltage reaches 100 kV. TVS can well satisfy the main demands of high voltage and current applications, and can also be used under a multi-crowbar circuit.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return