• 中文核心期刊要目总览
  • 中国科技核心期刊
  • 中国科学引文数据库(CSCD)
  • 中国科技论文与引文数据库(CSTPCD)
  • 中国学术期刊文摘数据库(CSAD)
  • 中国学术期刊(网络版)(CNKI)
  • 中文科技期刊数据库
  • 万方数据知识服务平台
  • 中国超星期刊域出版平台
  • 国家科技学术期刊开放平台
  • 荷兰文摘与引文数据库(SCOPUS)
  • 日本科学技术振兴机构数据库(JST)

Observation of the Two-Dimensional Distribution of Impurity Line Emissions Using a Space-Resolved EUV Spectrometer in LHD

Observation of the Two-Dimensional Distribution of Impurity Line Emissions Using a Space-Resolved EUV Spectrometer in LHD

  • 摘要: A space-resolved EUV spectrometer for measuring the one-dimensional distribution of impurity line emissions in Large Helical Device (LHD) has been upgraded to measure two- dimensional distributions of impurity line emissions with an extension of working wavelength range to 30x650Å. The two-dimensional measurement is performed by scanning the observation chord horizontally. A rectangular plasma region of 520x700 mm2 in vertical and horizontal sizes can be observed during a single horizontal scan. The horizontal scan requires a time duration of 5 s at least. The spatial resolution is 10 mm in the vertical direction when a spatial-resolution slit of 0.2 mm in width is adopted. Although a spatial resolution in the toroidal direction is 75 mm, it is a function of CCD exposure time and horizontal scanning speed. Two-dimensional distribution of EUV line emissions from several impurities has been successfully observed for the first time from steady discharges in LHD. In this paper two-dimensional distributions of He II (303.78 Å), C V (40.27 Å), C VI (33.73 Å) and Fe XX (132.85 Å) located at di®erent radial positions are presented with simple analysis on the magnetic field structure of LHD.

     

    Abstract: A space-resolved EUV spectrometer for measuring the one-dimensional distribution of impurity line emissions in Large Helical Device (LHD) has been upgraded to measure two- dimensional distributions of impurity line emissions with an extension of working wavelength range to 30x650Å. The two-dimensional measurement is performed by scanning the observation chord horizontally. A rectangular plasma region of 520x700 mm2 in vertical and horizontal sizes can be observed during a single horizontal scan. The horizontal scan requires a time duration of 5 s at least. The spatial resolution is 10 mm in the vertical direction when a spatial-resolution slit of 0.2 mm in width is adopted. Although a spatial resolution in the toroidal direction is 75 mm, it is a function of CCD exposure time and horizontal scanning speed. Two-dimensional distribution of EUV line emissions from several impurities has been successfully observed for the first time from steady discharges in LHD. In this paper two-dimensional distributions of He II (303.78 Å), C V (40.27 Å), C VI (33.73 Å) and Fe XX (132.85 Å) located at di®erent radial positions are presented with simple analysis on the magnetic field structure of LHD.

     

/

返回文章
返回