Design Study of Top Lid with Clamp Structure in JT-60SA Cryostat

Design Study of Top Lid with Clamp Structure in JT-60SA Cryostat

  • 摘要: JT-60SA is a fully superconducting coil tokamak upgraded from the JT-60U. This paper focused on the integrity of the top lid of cryostat in JT-60SA. The design requirement for the cryostat in normal operations is to achieve vacuum insulation of 10¡3 Pa, and the top flange of the top lid is lightly welded onto its body flange. The weld is tensile-loaded by bending deformation of the top lid due to vacuum pressure of external 0.1 MPa. This weld integrity is evaluated with tensile-load reduction, which results in clamp reinforcement. The structural integrity of the top lid is validated.

     

    Abstract: JT-60SA is a fully superconducting coil tokamak upgraded from the JT-60U. This paper focused on the integrity of the top lid of cryostat in JT-60SA. The design requirement for the cryostat in normal operations is to achieve vacuum insulation of 10¡3 Pa, and the top flange of the top lid is lightly welded onto its body flange. The weld is tensile-loaded by bending deformation of the top lid due to vacuum pressure of external 0.1 MPa. This weld integrity is evaluated with tensile-load reduction, which results in clamp reinforcement. The structural integrity of the top lid is validated.

     

/