Advanced Search+
A. A. AZOOZ, Sabah I. WAYSI. An Alternative Empirical Formula for Positive Corona Discharge I-V Characteristics in Point-to-Plate Electrode Geometry[J]. Plasma Science and Technology, 2014, 16(3): 211-218. DOI: 10.1088/1009-0630/16/3/07
Citation: A. A. AZOOZ, Sabah I. WAYSI. An Alternative Empirical Formula for Positive Corona Discharge I-V Characteristics in Point-to-Plate Electrode Geometry[J]. Plasma Science and Technology, 2014, 16(3): 211-218. DOI: 10.1088/1009-0630/16/3/07

An Alternative Empirical Formula for Positive Corona Discharge I-V Characteristics in Point-to-Plate Electrode Geometry

  • Experimental data are presented for a study on the dependence of the I-V character- istics of the corona discharge on pressure and electrode spacing using point-to-plane electrode con- figuration. These experimental data are obtained by a fast, automatic computer data-acquisition system. The data are used to suggest an alternative dimensionally self-consistent empirical equa- tion for the parameterization of the I-V curves. The formula eliminates the need for any prior assumptions concerning the inception voltage, as is customary in this type of work.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return