Advanced Search+
Houyin WANG (王厚银), Jiansheng HU (胡建生), Yaowei YU (余耀伟), Bin CAO (曹斌), Jinhua WU (吴金华), Guoqing SHEN (沈国清), Zhao WAN (万朝), EAST Contributors. Higher resolution helium measuring system for deuterium plasma on EAST tokamak via normal Penning gauge[J]. Plasma Science and Technology, 2017, 19(1): 15601-015601. DOI: 10.1088/1009-0630/19/1/015601
Citation: Houyin WANG (王厚银), Jiansheng HU (胡建生), Yaowei YU (余耀伟), Bin CAO (曹斌), Jinhua WU (吴金华), Guoqing SHEN (沈国清), Zhao WAN (万朝), EAST Contributors. Higher resolution helium measuring system for deuterium plasma on EAST tokamak via normal Penning gauge[J]. Plasma Science and Technology, 2017, 19(1): 15601-015601. DOI: 10.1088/1009-0630/19/1/015601

Higher resolution helium measuring system for deuterium plasma on EAST tokamak via normal Penning gauge

Funds: funded by National Magnetic Confinement Fusion Science Program of China under Contract No. 2013GB114004, No.2014GB106005 & No. 2015GB101000 and National Nature Science Foundation of China under Contract No. 11625524,No. 11321092 and No. 11405210. This work was also partly supported by the Japan Society for the Promotion of Science National Research Foundation of Korea-National Science Foundation of China (JSPS-NRF-NSFC) A3 Foresight Program in the field of Plasma Physics (NSFC No. 11261140328).
More Information
  • Received Date: March 27, 2016
  • Although the deuterium and helium have almost the same mass, a Penning Optical Gas Analyzer (POGA) system on the basis of the spectroscopic method and Penning discharging has been designed on EAST, since 2014. The POGA system was developed successfully in 2015, it was the first time that EAST could detect helium partial pressure in deuterium plasma (wall conditioning and plasma operation scenario). With dedicated calibration and proper adjustment of the parameters, the minimum concentration of helium in deuterium gas can be measured as about 0.5% instead of 1% on the other tokamak devices. Moreover, the He and D2 partial pressures are measured simultaneously. At present, the measurable range of deuterium partial pressure is 1×10−7 mbar to 1×10−5 mbar, meanwhile the range of helium is 1×10−8 mbar to 1×10−5 mbar. The measurable range can be modified by means of the adjustment of POGA system’s parameters. It is possible to detect the interesting part of the gas with a time resolution of less than 5 ms (the 200 ms because of conductance of transfer pipe at present). The POGA system was routinely employed to wall conditioning and helium enrichment investigation in 2015. Last but not the least, the low temperature plasma of POGA is generated by normal penning gauge Pfeiffer IKR gauge instead of Alcatel CF2P, which has been suspended for a few years and was used for almost all the POGA systems in the world.
  • [1]
    Shimada M et al 1981 Physics Review Letter 47 796
    [2]
    Kikuchi M 1990 Nucl. Fusion 30 265
    [3]
    Redi M H and Cohen S A 1990 J. Nucl. Mater. 176 262
    [4]
    Reiter D, Wolf G H and Kever H 1990 Nucl. Fusion 30 2141
    [5]
    Gao X the EAST Team 2008 Phys. Lett. A 372 2286
    [6]
    Engelmann U et al 1991 Nucl. Instrum. Methods Phys. Res. A302 345
    [7]
    Finken K H et al 1992 Rev. Sci. Instrum. 63 l
    [8]
    Denner T, Finken K H and Mank G 1996 Rev. Sci. Instrum. 67 10
    [9]
    Andrew P et al 1993 Nucl. Fusion 33 1389
    [10]
    Bosch H-S et al 2001 J. Nucl. Mater. 290 836
    [11]
    Az′eroual A et al 2000 Nucl. Fusion 40 1651
    [12]
    Wang H Y et al 2008 J. Phys.: Conf. Ser. 100 343
  • Related Articles

    [1]Monzurul K AHMED, Om P SAH. Solitary kinetic Alfvén waves in dense plasmas with relativistic degenerate electrons and positrons[J]. Plasma Science and Technology, 2019, 21(4): 45301-045301. DOI: 10.1088/2058-6272/aaf20f
    [2]Nimardeep KAUR, Kuldeep SINGH, Yashika GHAI, N S SAINI. Nonplanar dust acoustic solitary and rogue waves in an ion beam plasma with superthermal electrons and ions[J]. Plasma Science and Technology, 2018, 20(7): 74009-074009. DOI: 10.1088/2058-6272/aac37a
    [3]Suyun ZHOU (周素云), Hui CHEN (陈辉), Yanfang LI (李艳芳). Breaking of a Langmuir wave in cold electron–positron–ion plasmas[J]. Plasma Science and Technology, 2018, 20(1): 14008-014008. DOI: 10.1088/2058-6272/aa8cc0
    [4]Monzurul K AHMED, Om P SAH. Solitary kinetic Alfvén waves in a dense electron–positron–ion plasma with degenerate electrons and positrons[J]. Plasma Science and Technology, 2017, 19(12): 125302. DOI: 10.1088/2058-6272/aa8765
    [5]Guiliang SONG (宋桂良), Huishan CAI (蔡辉山). Linear tearing modes in an electron-positron plasma[J]. Plasma Science and Technology, 2017, 19(4): 45002-045002. DOI: 10.1088/2058-6272/aa5801
    [6]Jianxun LIU (刘建勋), Yanyun MA (马燕云), Xiaohu YANG (杨晓虎), Jun ZHAO (赵军), Tongpu YU (余同普), Fuqiu SHAO (邵福球), Hongbin ZHUO (卓红斌), Longfei GAN (甘龙飞), Guobo ZHANG (张国博), Yuan ZHAO (赵媛), Jingkang YANG (杨靖康). High-energy-density electron beam generation in ultra intense laser-plasma interaction[J]. Plasma Science and Technology, 2017, 19(1): 15001-015001. DOI: 10.1088/1009-0630/19/1/015001
    [7]REN Yanqiu (仁艳秋), LI Gun (李滚), DUAN Wenshan (段文山). Damping Solitary Wave in a Three-Dimensional Rectangular Geometry Plasma[J]. Plasma Science and Technology, 2016, 18(2): 108-113. DOI: 10.1088/1009-0630/18/2/02
    [8]ZHU Zhenni(朱珍妮), WU Zhengwei(吴征威), LI Chunhua(李春华), YANG Weihong(杨维纮). Electron Acoustic Solitary Waves in Magnetized Quantum Plasma with Relativistic Degenerated Electrons[J]. Plasma Science and Technology, 2014, 16(11): 995-999. DOI: 10.1088/1009-0630/16/11/01
    [9]ZHANG Liping(张丽萍), SU Junyan(苏俊燕), LI Yanlong(李延龙). Propagation of Nonlinear Solitary Waves in Nonuniform Dusty Plasmas with Two-Ion Temperature[J]. Plasma Science and Technology, 2014, 16(3): 177-181. DOI: 10.1088/1009-0630/16/3/01
    [10]MA Donglin (马栋林), ZHANG Xijun (张玺君), ZHANG Liping (张丽萍). The Effects of Inhomogeneity and Adiabatic Dusty Charge Fluctuation on Solitary Waves[J]. Plasma Science and Technology, 2013, 15(1): 7-11. DOI: 10.1088/1009-0630/15/1/02

Catalog

    Article views (389) PDF downloads (715) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return