  • Diagnostic neutral beam (DNB), combined with spectral diagnostics, is employed to measure the ion temperature in HT-7. The factors affecting the extracted beam are studied in the experiment for the high performance diagnostic neutral beam. A 6.5 A extracted hydrogen current at 43 keV of 100 ms was obtained after optimization. The extracted beam has a proton ratio as high as 40%, and can penetrate into the core plasma after neutralization to measure the ion temperature effectively.