YANG Zaihong (杨再宏), YOU Haibo (游海波), XIAO Jun(肖军), YE Yanlin (叶沿林). Performance Calibration using Cosmic Rays for the Multi-neutron Correlation Spectrometer[J]. Plasma Science and Technology, 2012, 14(6): 464-468. DOI: 10.1088/1009-0630/14/6/06
Citation:
YANG Zaihong (杨再宏), YOU Haibo (游海波), XIAO Jun(肖军), YE Yanlin (叶沿林). Performance Calibration using Cosmic Rays for the Multi-neutron Correlation Spectrometer[J]. Plasma Science and Technology, 2012, 14(6): 464-468. DOI: 10.1088/1009-0630/14/6/06
YANG Zaihong (杨再宏), YOU Haibo (游海波), XIAO Jun(肖军), YE Yanlin (叶沿林). Performance Calibration using Cosmic Rays for the Multi-neutron Correlation Spectrometer[J]. Plasma Science and Technology, 2012, 14(6): 464-468. DOI: 10.1088/1009-0630/14/6/06
Citation:
YANG Zaihong (杨再宏), YOU Haibo (游海波), XIAO Jun(肖军), YE Yanlin (叶沿林). Performance Calibration using Cosmic Rays for the Multi-neutron Correlation Spectrometer[J]. Plasma Science and Technology, 2012, 14(6): 464-468. DOI: 10.1088/1009-0630/14/6/06
School of Physics and State Key Lab. of Nucl. Phys. and Tech., Peking University, Beijing 100871, China
Funds: supported by the National Basic Research Program of China ( No. 2007CB815002) and the National Natural Science Foundation of China (Nos.11035001,10775003, 10827505,10821140159)
Efficient calibration methods have been applied to a complex neutron detector array by using the cosmic-ray muons. Through a differential operation on the time difference spectrum, the two edges of this spectrum can be precisely determined, corresponding to the geometrical two ends of the bar, and therefore the relationship between the position and time difference spectrum can be deduced for each bar. The alignment between different bars is realized by choosing cosmic-rays which are perpendicular to the bars. The position resolutions are extracted through a track fitting procedure which uses all tracks detected coincidently by the whole system, together with a simulation analysis. A method is also developed to calibrate the deposited energy by using cosmic-rays at different incident angles.
Li, S., Zeng, F., Zhang, Q. et al. Study on a compact pulse forming line-Marx type high voltage pulse generator. Review of Scientific Instruments, 2025, 96(1): 014707.
DOI:10.1063/5.0233985
2.
Luo, W., Ren, C., Huang, B. et al. Impact of overvoltage on the mode transition of the spark gap switch: from edge breakdown to stochastic breakdown. Plasma Sources Science and Technology, 2024, 33(11): 115003.
DOI:10.1088/1361-6595/ad8aeb
3.
Wang, Y., Li, J., Jiang, M. et al. The effects of pulse voltage rise time on the nanosecond pulsed breakdown of nitrogen spark switch at atmospheric pressure with 3D PIC-MCC model. Physics of Plasmas, 2023, 30(4): 043901.
DOI:10.1063/5.0138011
4.
Jia, Y., Xie, K., Ding, Y. et al. Special issue on selected papers from CEPC 2021. Plasma Science and Technology, 2022, 24(7): 070101.
DOI:10.1088/2058-6272/ac75c9